Menu

Mobile RS emulsion regeneration station

Do you have any questions?

Mobile RS emulsion regeneration station

In an era of ever-increasing industrial wastewater disposal costs, the RS-M900 mobile regeneration system is a device that brings real savings to any company using machining coolants. MOBILE EMULSION REGENERATION SYSTEM RS-M900 is a compact device that combines three functions:

  • filtration of particulate matter from 100 to 300 microns
  • separation of foreign oils
  • removal of microorganisms

The above coolant purification processes are optimally designed.

  • separation of up to 99% of foreign oils
  • filtration of particulate matter from 100 to 300 microns
  • removal of microorganisms up to 90%
  • extending the life of the coolant
  • extending tool life
  • reduction in disposal costs
  • oil mist reduction on the shop floor
  • operation without stopping machines, in by-pass mode
  • recovery of contaminated and oily coolant
  • reduction of irritation and allergies in machine operators
  • reduction in machine downtime due to emulsion replacement
  • dedicated to restore the proper parameters of the coolant.

RS-M900
RS-M900APD
RS-M900AP
RS-M900A
RS-M900P
RS-M900PD

Why is it worth it?

OPERATION IN BY-PASS MODE

SEPARATION OF UP TO 99% OF FOREIGN OILS

REMOVAL OF MICROORGANISMS UP TO 90%

FILTRATION OF PARTICULATE MATTER FROM 100 TO 300 MICRONS

OIL MIST REDUCTION ON THE SHOP FLOOR

Product photos

Video

Technical details

RS-M900 RS-M900APD RS-M900AP RS-M900A RS-M900P RS-M900PD
A - emulsion lifting station
P - pH monitoring
D - automatic dosing station
DIMENSIONS AND WEIGHT
Height 1210 mm
Length 1401 mm 1531 mm 1401 mm 1401 mm 1401 mm 1531 mm
Width 680 mm
Weight 180 kg 235 kg 230 kg 200kg 182 kg 215 kg
ELECTRICAL SYSTEM
Power supply 230 VAC
50 Hz. 10 A
400 VAC
50 Hz. 10 A
400 VAC
50 Hz. 10 A
400 VAC
50 Hz. 10 A
230 VAC
50 Hz. 10 A
230 VAC
50 Hz. 10 A
Power consumption 60 W 200 W 180 W 180 W 80 W 100 W
Control voltage 24V DC
Power cord length 5m
PNEUMATIC SYSTEM
Required pressure of the compressed air connection 7 ÷ 8 bar
Compressed air demand 200 Nl/min
TECHNOLOGICAL SYSTEM
Particulate matter filtration 1000 µm
Separation of foreign oils 99%
Removal of microorganisms 90%
Capacity of the oil separator chamber 140 l
Capacity of the ozonator chamber 50 l
Suction height 1 m
Pumping height (return) by gravity 1,5 m 1,5 m 1,5 m 1,5 m by gravity
Maximum efficiency of the system approximately 900 l/h
PH measurement range ND 0.00 ÷ 14.00 pH 0.00 ÷ 14.00 pH ND 0.00 ÷ 14.00 pH 0.00 ÷ 14.00 pH
Operating temperature (medium) 10 ÷ 40 °C
Performance of the ozone generator up to 7000 mg/h
Diameter and length
of the suction hose/suction line
of the contaminated emulsion
¾”, 3 m
Diameter and length
of the return hose/return lance
of the purified emulsion
1 ¼”, 3 m ¾”, 3 m ¾”, 3 m ¾”, 3 m 1 ¼”, 3m 1 ¼”, 3m
Separated oil tank capacity 10 l
Noise level 70,7 dB
EXECUTION
Cart powder-coated steel
Oil separator/ozonator separator stainless steel